What is the maximum input power of the Magnifica Evo?

The maximum input power of the Magnifica Evo is 1450 W. (Page 2)

2

How do I perform an Encoder Reset on the Magnifica Evo?

To perform an Encoder Reset, first enter Test Mode as described, then press the Pre-Ground button. The Pre-Ground LED will remain steadily on while the reset is in progress and will turn off when complete. To validate the reset, you must then start the appliance normally and perform a manual rinse — the infuser must be clean and moving smoothly for the reset to be validated correctly. (Page 13)

3

How do I read the machine's usage statistics?

To access statistics, make sure the appliance is in ready-for-coffee mode, then hold the Settings and Pre-Ground buttons pressed for at least 5 seconds. You can then press specific buttons to view data such as number of coffee beverages, number of steam deliveries, number of descaling processes, litres of water used, and number of filters installed. To exit statistics mode, press the Settings button again or wait 120 seconds without operating the machine. (Page 14-15)

4

How does the machine display statistics values?

The machine displays statistics values through sequential flashing of indicator lights, with the Descale light representing the tens digit and the Grounds Container light representing the units digit. For example, a total of 24 coffee beverages would be shown as 4 flashes of the Descale light followed by 2 flashes of the Grounds Container light. (Page 15)

5

What is the correct temperature for coffee output on the Magnifica Evo?

The optimal indicative temperature measurement for coffee should be 83°C ± 3°C, measured at approximately 2–10mm from the coffee spout. To perform an accurate coffee temperature test, you should set the temperature to maximum, run 1-2 rinse cycles to warm up the hydraulic circuit, and wait until at least 20ml of coffee has been delivered before measuring. (Page 18)

6

What are the steps involved in espresso delivery?

During espresso delivery, the thermoblock activates first, followed by the grinder for a set timing based on coffee taste selection. The pump then activates briefly for pre-infusion before restarting for full coffee delivery, after which the infuser moves away from the mechanical valve, releases the coffee pod, and the mechanical valve discharges excess water and coffee to the expansion chamber and drip tray. (Page 7)

Show 13 more questions

Full Manual

18 pages
Page 1

Doc. Nr.: DSDL_21007_A

[1]

Data Sheet and Service Manual

Magnifica Evo

Ecam29X.2Y, Ecam29X.3Y, Ecam29X.4Y

Date: 11.05.2021

Table Of Contents:

  • TECHNICAL DATA ................................................................................................................................... 2
  • HYDRAULIC DIAGRAM ........................................................................................................................... 3
  • WIRING DIAGRAM .................................................................................................................................... 4
  • WORKING PRINCIPLE............................................................................................................................. 6
  • TEST MODE ............................................................................................................................................. 10
  • STATISTICS READING .......................................................................................................................... 14
  • 7. Troubleshooting……………………………………………………………………………………………………………………….16

    Page 2

    Doc. Nr.: DSDL_21007_A

    [2]

    1. Technical Data

    Voltage

    220-240V / 50-60 Hz MAX. Input power

    1450 W

    Stand-by Button OFF

    0,19 Wh (plug inserted but machine OFF)

    Components

    Pump

    220-240V AC - 48 W – Bar 15 Grinder motor

    230V Ac

    Transmission motor

    230V DC with position encoder

    Thermoblock

  • Temperature probe
  • NTC sensor: operating set point

  • Thermal fuse TCO
  • 192 °C

  • Heating element
  • 230V Ac – 1400 W

    Page 3

    Doc. Nr.: DSDL_21007_A

    [3]

    2. Hydraulic Diagram

    Page 4

    Doc. Nr.: DSDL_21007_A

    [4]

    3. Wiring Diagram

    Page 5

    Doc. Nr.: DSDL_21007_A

    [5]

    Page 6

    Doc. Nr.: DSDL_21007_A

    [6]

    4. Working Principle

    4.1. Microswitches And Sensors

    Microswitches

    Function Logic

    M1 = Upper Microswitch

    Detects when the infuser is on top position “NC”, it opens when the infuser is in top position

    M2 = Lower Microswitch

    Detects when the infuser is on down position “NO”, it closes when the infuser is in down position

    M3 = Drawer Microswitch

    Detects when the drip tray is in correct position Changeover micro switch. When the drip tray is inserted:
  • the contact for the drip tray
  • detection is OPEN;
  • the contact for the transmission
  • motor power supply is CLOSED.

    M4 = Water Tank

    Microswitch

    Detects the presence of the water tank Changeover micro switch. When the water tank is inserted:
  • the contact for the water tank
  • detection is OPEN;
  • the contact for the transmission
  • motor power supply is CLOSED.

    M5 = Hot Water Tap

    Microswitch

    Detects when the hot water tap is in I position. “NO”, it closes when the hot water tap is in I position.

    Reed And Encoder

    Function Logic

    Reed Sensor Low Water

    Tank

    Detects when the water level is at minimum

    Hall Sensor Encoder

    Detects rotations of transmission motor

    Page 7

    Doc. Nr.: DSDL_21007_A

    [7]

    4.2. Coffee Delivery

    Espresso delivery steps:

  • Thermoblock is activated
  • Grinder is activated for a certain timing (based on the coffee taste selection)
  • Infuser moves to the mechanical valve
  • Pump is activated for a couple of seconds for pre-infusion
  • Pump restarts for coffee delivering
  • Pump and thermoblock stop
  • Infuser moves away from the mechanical valve and releases the coffee pod
  • Mechanical valve discharges excess water/coffee to the expansion chamber and drip tray
  • Infuser is moved back to the “Coffee Ready” position
  • Cold water

    Hot water

    Coffee

    Discharge

    Page 8

    Doc. Nr.: DSDL_21007_A

    [8]

    4.3. Hot Water Delivery

    Hot water delivery steps:

  • Thermoblock is activated
  • Pump is activated in fast pulsing mode for a certain timing
  • Hot water is delivered through the hot water spout
  • Pump stops, Thermoblock is deactivated
  • Cold water

    Hot water

    Discharge

    Page 9

    Doc. Nr.: DSDL_21007_A

    [9]

    4.4. Steam Preparation

    Steam delivery steps:

  • Thermoblock is activated (setting temperature higher than 100°C)
  • Pump is activated in slow pulsing mode for a certain timing
  • The steam is delivered from the spout
  • Pump stops, Thermoblock is deactivated
  • Cold water

    Steam

    Discharge

    Page 10

    Doc. Nr.: DSDL_21007_A

    [10]

    5. Test Mode

    5.1. Procedure To Activate Test Modes

  • The appliance must be plugged-in and in stand-by mode.
  • Remove the drip tray. The GROUNDS CONTAINER icon will flash
  • Hold the combination of the below three button pressed (depending on the model):
  • Ecam29X.2Y

    Ecam29X.3Y

    Ecam29X.4Y

    until the GROUNDS CONTAINER icon will turn OFF and the LEDs of the below buttons (depending on the model) will start flashing:

    Ecam29X.2Y

    Page 11

    Doc. Nr.: DSDL_21007_A

    [11]

    Ecam29X.3Y

    Ecam29X.4Y

  • Insert the grounds container and press one of the buttons indicated in the next paragraphs to start the
  • corresponding test function.

    IMPORTANT NOTICE: The access to the desired test function must be done within 10 seconds, otherwise the machine will automatically come back to stand-by mode.

    Page 12

    Doc. Nr.: DSDL_21007_A

    [12]

    5.2. Load Test Mode

    After having accessed the test mode as indicated on paragraph 5.1, press the first beverage icon from the left (STEAM button) to access the LOAD TEST MODE:

    The LED of each button linked to the activation of a component will illuminate steadily white. Hold the desired button pressed to activate the corresponding load, the LED of the button will flash slowly to indicate the activation of the load:

    NOTICE: When the DOWN micro switch is reached by the infuser, the DESCALE LED will blink fast. NOTICE: When the UP micro switch is reached by the infuser, the SETTINGS LED will blink fast.

    Page 13

    Doc. Nr.: DSDL_21007_A

    [13]

    5.3. Display Test Mode

    After having accessed the test mode as indicated on paragraph 5.1, press the second beverage icon from the left (ESPRESSO button) to access the DISPLAY TEST MODE:

    During the display test mode all the LEDs are lit up. When a button is pressed, only the LED of that button remains ON, while those of all the other buttons will be turned OFF:

    In particular, by pressing each of the AROMA buttons, in addition to the button LED, also the two neighbor warning LEDs will illuminate steadily:

    NOTICE: The DISPLAY TEST MODE will reset the following settings in the appliance:  First run: the machine will ask again for hydraulic circuit filling.  Filter installation: if the filter installation function was enabled, it will be disabled.

    Page 14

    Doc. Nr.: DSDL_21007_A

    [14]

    5.4 Encoder Reset

    After having accessed the test mode as indicated on paragraph 5.1, press the PRE-GROUND button to perform the ENCODER RESET, i.e. the reset of the value of the maximum height of the infuser:

    The PRE-GROUND LED will remain steady ON while the reset is in progress, then it will go OFF when the reset is completed.

    IMPORTANT: To complete the encoder reset procedure, start the appliance normally and perform a manual rinse with the dedicated button. The infuser must be clean and smooth in its movements to allow the encoder reset to be validated correctly.

    6. Statistics Reading

    The appliance allows the reading of the statistics data to understand exactly how the machine operated along the time. To access the STATISTICS function:
  • make sure the appliance is ready to use (i.e. in ready-for-coffee mode);
  • hold the SETTINGS and PRE-GROUND buttons pressed for at least 5 seconds:
  • The LEDs of the buttons dedicated to read the statistics values will illuminate steadily.

    Page 15

    Doc. Nr.: DSDL_21007_A

    [15]

    Press the desired button to display the corresponding statistics data:

    Button

    Statistic Data

    ESPRESSO (Beverage 2) Number of Coffee Beverages STEAM (Beverage 1) Number of Steam Deliveries

    Descale

    Number of Descaling Processes

    X2/Rinse

    Litres of Water

    Mid Aroma Coffee Bean

    Number of Filters Installed

    After having pressed the desired button, the appliance will display the corresponding statistic value with the sequential flashing of the below lights:

    Example: To display a total amount of 24 coffee beverages, the appliance will display:

  • 4 flashings of the DESCALE light;
  • followed by 2 flashings of the GROUNDS CONTAINER light.
  • NOTICE: To exit the statistics mode, press the SETTINGS button again or wait for 120 seconds without operating on the machine. The appliance will come back to the ready to use mode.

    Page 16

    Doc. Nr.: DSDL_21007_A

    [16]

    7. Troubleshooting

    7.1. Possible Tests Which Can Be Executed From The Test Mode

    A. Coffee Circuit Flow Activation

  • Move the infuser to the UP position (MOTOR UP).
  • Activate the pump.
  • The water will pass through the flow meter, the Thermoblock, the mechanical valve, the infuser and will come out from the coffee spout.

    B. Hot Water Circuit Flow Activation

  • The infuser does not have to be in upper position.
  • Open the hot water tap.
  • Activate the pump.
  • The water will pass through the flow meter, the Thermoblock, the hot water tap. Finally it will come out from the hot water spout.

    7.2. Electric Checks Directly On The Components

    A. Heating Elements Resistance Check

  • Thermoblock resistance value: ≈ 35 Ohms.
  • B. Resistance/Temperature Characteristics For Ntc Sensor

  • Resistance/temperature characteristics for the thermoblock NTC:
  • Page 17

    Doc. Nr.: DSDL_21007_A

    [17]

    C. Ground Check Point For The Appliance

    In order to check the main ground connection of the appliance insert the ground tester probe from the round hole located on the basement of the appliance on the Thermoblock side until it will touch the Thermoblock metal surface, as displayed in the below picture:

    Page 18

    Doc. Nr.: DSDL_21007_A

    [18]

    7.3. Coffee Temperature Test

    Complains from end users about coffee temperature are quite frequent. They are mainly due to incorrect appliance adjustments or to an incorrect expectation by the customer. A coffee temperature measurement is required all the times any of these complaints are encountered. To perform the coffee temperature test, follow in sequence the below steps:  Turn the appliance ON.  Set the temperature to MAX level.  Run 1-2 rinse cycles, to warm up the hydraulic circuit.  Set the temperature to the maximum level.  Select to prepare an X2 ESPRESSO COFFEE (2 cups recipe, refer to the user manual for more details).  Start the coffee preparation.  Wait until at least 20ml of coffee have been delivered into the cup.  Measure the coffee flow temperature at about 2÷10mm from the coffee spout, as shown in the below picture:

    The optimal indicative temperature measurement for coffee should be 83°C±3°C.

    More from De'Longhi