20 totalHow do I restore the factory settings?
Press any key once an error (Er) appears on screen to reset and restore all parameter values to default.
What power supply options are available for the STC-1000?
The STC-1000 can be powered by either AC 90~250V at 50/60Hz or DC 12V/DC 24V. Consult a professional technician for proper wiring based on your specific application.
How do I check the current parameter settings on the display?
In normal working status, the screen displays the real-time temperature. Press the designated button to display the set temperature value, press it again to show the difference value, and press the back button to return to the normal display.
How do I power on and off the STC-1000?
Hold the back button for a few seconds to power off the device. Hold the back button for 3 seconds to power on the device.
What are the physical dimensions and mounting requirements for the STC-1000?
The device dimensions are 75mm (L) x 34mm (W) x 85mm (D), with a mounting size of 71mm (L) x 29mm (W). The power consumption is ≤3W, and the operating ambient temperature range is -20°C to 70°C with humidity between 20% to 85% RH.
How do I set the temperature on the STC-1000?
In normal working status, press and hold the S button for 3 seconds to enter parameter setting mode. Use the buttons () to select F1 (temperature set value) and adjust it using or . The default temperature set value is 10℃, with a range of -50~99℃.
Show 14 more questions
What does the 'cool' indicator light mean?
What causes the 'Er' error display?
How can I adjust the compressor delay time?
What is the difference value setting for?
Where can I obtain spare parts or technical support?
Can I change the device's calibration temperature?
How do I power off the STC-1000?
What happens if a sensor error occurs?
What should I do if the screen displays 'Er.' when I power on the device?
How do I enter parameter setting mode on the STC-1000?
What happens if I don't save my parameter changes within a certain time?
How does the heating mode work on this temperature controller?
What is the refrigerating control output delay protection feature?
What temperature control range does the STC-1000 support?