How do I properly connect the air/gas supply to the Spectrum 375?
Use only clean, dry air with 90 to 120 psi (621 to 827 kPa) pressure. Obtain a hose with 1/4 NPT right-hand thread fitting, wrap the threads with teflon tape or apply pipe sealant, and install the fitting in the gas/air inlet opening. Route the hose to your gas/air supply. Ensure that all connections are properly assigned and tightened, and verify that correct air pressure and airflow are set to prevent torch overheating. (Page 15)
From the official Miller Spectrum 375 Plasma Cutter manual, page 15