How do I perform maintenance to prevent compressor overheating?

Monitor the compressor discharge temperature and adjust operating frequency based on preset values: below 212°F, no adjustment needed; between 212-223°F reduces frequency by 2 Hz every 30 seconds.

From the official Sanyo Ahx0752 Series Split System Air Conditioner manual, page 45